Sign In | Join Free | My ccnmag.com
China FLY AUTOMATION logo
FLY AUTOMATION
Automation Industry Expert . Focused on Pneumatic Components 15 years!
Verified Supplier

17 Years

Home > Pulse Jet Valves >

RCAC20DD4 3/4" Pulse Valve Normal DRESSER NUT Temperature K2034 DD Series Electric Control Aluminium Alloy

FLY AUTOMATION
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

RCAC20DD4 3/4" Pulse Valve Normal DRESSER NUT Temperature K2034 DD Series Electric Control Aluminium Alloy

Brand Name : FLY, AIRWOLF or others

Model Number : RCAC20DD4

Certification : ISO 9001,CE

Place of Origin : China

MOQ : 1 piece

Price : price negotiable

Payment Terms : T/T in advance,Western Union,Paypal,Credit card

Supply Ability : 2000 pcs/month

Delivery Time : 5 working days

Packaging Details : carton

Power : Pneumatic

Valve body material : Aluminium (diecast)

Pressure : 30-860KPA

Temperature : Normal Temperature

Contact Now

RCAC20DD4 3/4" Normal Temperature K2034 DD Series electric control Aluminium Alloy Pulse Valve

Description

High performance diaphragm valve with dresser nut ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Maintenance
Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually.
Approvals
Integrally piloted valves meet the requirements of:
. Atex II 2D Mechanical
. CSA (C&US)
C22.2 No. 139-1982 UL Std No. 429
. C-Tick - integral pilots
. EMC (89/336/CE) - integral pilots
Installation
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.

Pressure Range: 30(5)-860(125) kPA(Psi)
Temperature Range: Nitrite Seals: -40°C (-40°F) to 82°C(179.6°F) fluororubber Seals: -29°C (-20.2°F) to 232°C (449.6°F)


Product pictures:

RCAC20DD4 3/4" Pulse Valve Normal DRESSER NUT Temperature K2034 DD Series Electric Control Aluminium Alloy

RCAC20DD4 3/4" Pulse Valve Normal DRESSER NUT Temperature K2034 DD Series Electric Control Aluminium Alloy

Serves time
0:00 - 23:59
From Monday to Sunday

Competitive Advantage

Our product features Our Services Guarantee:
1) Competitive price 1) Prompt respond (Reply with 24 hours)
2) Good quality 2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging 3) Registration support.
4) Produce according to Customers’ instruction 4) Photos/videos are available during production.
5) None delay shipment 5) Loading inspection, and send loading photos before shipment.

Introduction
Electromagnetic pulse valve refers to the gas through the valve in instantaneous once a electrical signal received. Just like pulse phenomena, it has the change of the short fluctuation. Therefore it is calls the pulse valve. The Industry standard definition of electromagnetic pulse valve for electromagnetic pilot valve and pulse valve together, diaphragm valve controlled by electrical signals.

Working principle
Electrical pulse controller send input signals so that the electromagnetic armature attracts the moving bar. Unclose the balancing hole to release the pressure gas in the back cavity of diaphragm quickly; the pressure gas in the front cavity holds up the diaphragm to open the passage and the valve starts cleaning.
The pulse signal disappears and the spring of the armature works immediately to resume the moving bar so as to close the balancing hole. The pressure gas in the back cavity of the diaphragm and the spring work together to close the passage the valve stops cleaning.
The damping hole in the diaphragm functions to damp the airflow when the moving bar of armature holds up for balancing and to transit the air to the back cavity as soon as the balancing hole is shut to close the passage and stop cleaning.


Product Tags:

3/4" FLY/AIRWOLF pulse valve

      

normal temperature FLY/AIRWOLF pulse valve

      

aluminium alloy FLY/AIRWOLF pulse valve

      
China RCAC20DD4 3/4" Pulse Valve Normal DRESSER NUT Temperature K2034 DD Series Electric Control Aluminium Alloy wholesale

RCAC20DD4 3/4" Pulse Valve Normal DRESSER NUT Temperature K2034 DD Series Electric Control Aluminium Alloy Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: FLY AUTOMATION
*Subject:
*Message:
Characters Remaining: (0/3000)